FDRPAS V5.4/24 will be available for shipping on April
30, 2003. If you want to upgrade to this release, contact Innovation.
FDRPAS V5.4/24 is required for support of the new
EMC Symmetrix DMX disk subsystem (DMX systems run the 5x69 microcode).
FDRPAS PROBLEM WHEN VTOC VOLUME SIZE DOES NOT MATCH
PHYSICAL VOLUME SIZE
A problem was recently discovered with FDRPAS. It
is an unusual condition, but when it occurs it can result in abends in
DADSM, errors in the Indexed VTOC (VTOCIX) and disabled VTOCIXs.
The problem occurs when you swap a volume whose physical volume size does not
match the volume size in the VTOC. For example, the physical volume might be
a 3390-9 (10017 cylinders) but the VTOC shows only the size of a 3390-3 (3339
cylinders). When you swap such a volume to another 3390-9, FDRPAS improperly
updates the VTOC and VTOCIX, resulting in errors on the new volume.
This is an unusual condition. When you initialize
a volume, ICKDSF automatically sets the VTOC size equal to the physical
volume size. Most products which move volumes, such as FDR and FDRPAS,
will recognize that the output volume is larger than the input and make
the necessary adjustments.
However, certain techniques for moving volumes to
new devices may not recognize a volume size change, so that after the move
the VTOC will still have the size of the original device. We know that
hardware migration techniques, such as PPRC, will not make any adjustment,
so if a 3390-3 is moved to a 3390-9 with PPRC or a similar technique, and
you later move that volume to another 3390-9 with FDRPAS, the problem could
occur.
Zap P-54.2069 is available for FDRPAS V5.4 levels
20 through 23 to detect this condition and fail the swap with the message
FDR124 REASON=4 VOL SIZE < DEVICE SIZE
The zap is included below and we recommend that all FDRPAS customers apply
it. FDRPAS V5.4 level 24 and above has this fix included. This will prevent
any harm which can occur from swapping such a volume.
Before you can swap a volume in this condition, you
must correct the VTOC and VTOCIX to show the correct volume size. To do
so,
1) run a ICKDSF "REFORMAT REFVTOC" operation to correct the volume
size.
2) run a FDRPAS "SWAPBUILDIX" function to refresh the VTOCIX on every
attached system.
Now the swap can be run successfully.
***** ZAP-ID# : P-54.2069
* DATE : 03.080
* PREREQ : V 5.4/20-23
* STATUS : NOT APPLIED
* SYMPTOMS : FDRPAS:FDRPASDC:MSG IEC605I, ABEND S0C4 OR DISABLED
* INDEXED VTOC AFTER A SWAP OF A VOLUME WITH AN
* ACTIVE INDEXED VTOC.
* PROBLEM : SWAP OF A 3390-9 TO ANOTHER 3390-9 HOWEVER THE
* VTOC FORMAT 4 HAS A DEV SIZE OF A 3390-3.
* FDRPAS UPDATED THE FORMAT 4 DEVICE SIZE TO THE
* REAL SIZE, HOWEVER THE INDEXED VTOC VPSM BLOCK
* WAS INCORRECTLY UPDATED.
* SOLUTION : FAIL THE SWAP WITH MESSAGE
* FDR124 REASON=4 VOL SIZE < DEVICE SIZE.
* NOTE : TO CORRECT THE PROBLEM RUN ICKDSF WITH
* REFORMAT REFVTOC ON THE VOLUME BEFORE THE SWAP,
* THEN RUN A FDRPAS SWAPBUILDIX TO KEEP THE OTHER
* SYSTEMS FROM DISABLING THE INDEX.
* MODULE(S) : FDRPASDC
*-
* THE FOLLOWING ZAP IS FOR LEVEL 20-23
*-
NAME FDRPASDC FDRPASDC
IDRDATA P542069
VER 00A0 D0A0,D0A2
VER 0814 D83A
REP 00A0 F440,6040,E5D6,D340,E2C9,E9C5,404C,40C4
REP 00B0 C5E5,C9C3,C540,E2C9,E9C5,4040,4040,03E8
REP 00C0 4900,D0BE,47D0,D83A,D21D,A02B,D0A0,D239
REP 00D0 CF54,A00F,4510,CD38,47F0,C340
REP 0814 D0C0
CHECKSUM CDB96
|